Region-specific hyperelastic parameters used in finite element modeling. Please see the main text for more details of how the parameters were obtained.

Mooney-Rivlin parameter c1 (kPa) Exponential multiplier c3 (kPa) Fiber scale factor c4 (−) Fiber concentration factor kf (−)
Cornea 150 39 184 2
Limbus 150 6 275 2
Anterior equator 150 35 181 0
Equator 150 16 196 0
Posterior equator 150 232 76 0
Posterior sclera 150 135 100 0
Peripapillary sclera 150 15 240 2