Skip to main content
. 2000 May;66(5):1769–1776. doi: 10.1128/aem.66.5.1769-1776.2000

TABLE 1.

Immobilization of L. monocytogenes and serovar Enteritidis in pure culture using titanous hydroxide and zirconium hydroxide

Organism Inoculum (CFU/ml) Avg % immobilizationa
Titanous hydroxide Zirconium hydroxide
L. monocytogenes 107 98 ± 2 98 ± 2
105 98 ± 3 97 ± 2
103 95 ± 3 98 ± 2
Serovar Enteritidis 107 98 ± 1 97 ± 2
105 98 ± 1 98 ± 1
103 98 ± 1 99 ± 1
a

Average percent immobilization (mean ± standard deviation) of three replicate samples; calculated as previously reported (8): [percent immobilization = (total population in sample before immobilization − total population in supernatant after immobilization) × 100/(total population in sample before immobilization)].