Table 4.
Method | Detector | Sample Preparation/Extraction | Analytical Methods | Target Compounds |
Ref. |
---|---|---|---|---|---|
GC | FID |
|
Column: (25m × 0.25mm, 0,33 μm, Dimethylpolysiloxane stationary phase) Temperatures (°C): Detector: 325; Injector: 325 Gas (mL/min): Helium (0.5) Injection type: Split ratio, 1:40 Injection volume (μL): 1 |
campesterol stigmasterol SIT total sterols |
[118] |
GC | FID/MS |
|
Column: (30 m × 0.32 mm, 0.25 μm, (poly (94%methyl/5% phenyl) silicone)) Temperatures (°C): column 250, injector 290, detector 290 Gas (mL/min): H2 (1) Injection type Split ratio, 1:25 Injection volume (μL): 1 |
campesterol stigmasterol SIT |
[22] |
GC | FID |
|
Column: (30 m × 0.32 mm, 0.25 μm) (5%-phenyl)-methylpolysiloxane stationary phase)/(30 m × 0.32 mm, 0.25 μm, (5%-phenyl) (1%-vinyl)-methylpolysiloxane stationary phase) Temperatures (°C): column 250, Injector 290, detector 290 Gas (mL/min): H2 (1) Injection type Split ratio, 1:25 Injection volume (μL): 1 |
17 phytosterols | [138] |
GC | FID/MS |
|
Column: (15 m × 0.32-mm,0.25 μm/5% diphenyl-95%-Dimethylpolysiloxane) Temperatures (°C): column 270, injector 280, detector 300. Gas (ml/min): helium (0.58) Injector type: split ratio, 17:1 Injection volume (μL): 0.5 |
SIT β-sitosteryl glucoside (BSSG) |
[139] |
GC | FID |
|
Column: (25 m × 0.32 mm, 17 μm/5% phenyl-methylsilicone or methyl silicone gum stationary phase) Temperatures (°C): Column 190→255, injector: 250, detector: 300 Gas (mL/min): helium 2/15/3; makeup helium 20/hydrogen 35/air 380 Injection volume (μL): 1 |
Campesterol Stigmasterol SIT |
[119] |
GC | FID/MS |
|
Column: (60 m × 0.25 mm, 0.25 um/5% phenyl methyl siloxane stationary phase) Temperatures (°C): column 80→325, detector 230. Gas (mL/min): helium (1) Injection volume (μL): 1 |
campesterol stigmasterol SIT total sterols |
[120] |
LC | APCI–MS |
|
1. Column: phenyl (150 mm × 3.9 mm, 3,5 μm) Mobile phase: 58% acetonitrile, 42% water Flow rate (mL/min): 1.1 (isocratic) 2. Column: ACE C18 (150 mm × 3.0 mm, 3 μm) Mobile phase: 90% methanol, 10% water Flow rate (mL/min): 0.80 (isocratic) Injection volume (μL): 5 for qualitative, 10 for quantitative measurement |
campesterol, cycloartenol, lupenone, lupeol, SIT, and stigmasterol (Standard Reference Materials containing saw palmetto) |
[39] |
HPLC | ESI-MS |
|
Column: C18 (250 × 3.0 mm, 5 μm) Mobile phase: 95% methanol: 5% water Flow rate (mL/min): 0.5 (isocratic) |
campesterol stigmasterol β-sitosterol |
[141] |
HPLC | UV |
|
Column: RP-18 (125-4 mm, 5 μm) Mobile phase: hexane, propan-1-ol (99.5:0.5; v/v) Flow rate (mL/min): 0.8−1 (isocratic) Injection volume (μL): 50 UV detection: 212 nm |
β-sitosterol | [142] |
UHPLC | UV/CAD |
|
Column: (100 × 2.1 mm, 1,7 μm) Phenyl-hexyl Mobile phase: acetonitrile: water Flow rate (mL/min): 0.9 (gradient) Temperature: 60 °C Inj. vol. (μL): 2 Run time (min): 8.5 |
ergosterol, brassicasterol, campesterol, campestanol, fucosterol, stigmasterol, stigmastanol, SIT esterified form |
[122] |
GC: gas chromatography; FID: flame ionization detection; BSTFA: bis-(trimethylsilyl) trifluoroacetamide; LLE: Liquid-liquid extraction; MS: mass spectrometry; TMCS: trimethylchlorosilane; MTSFA: N- methyl-N-(trimethylsilyl) fluoroacetamide; LC-liquid chromatography; APCI: atmospheric pressure chemical ionization; ESI: ionization by electrospray; UV: ultraviolet; HPLC: high liquid chromatography; UHPLC: ultra-high liquid chromatography; CAD: Charged aerosol detector.