Skip to main content
. 2023 Apr 9;13(4):422. doi: 10.3390/membranes13040422

Table 2.

Some parameters of the membrane preparation process: porosity and crystallinity degree of the obtained membranes.

Sample Swelling Time, min Swelling Degree (Q) Volume Fraction of O-xylene in Swollen Film Volume Porosity (P) Mass Fraction of UHMWPE in the Swollen Film Crystallinity Degree (α)
M1 20 1.7 0.630 0.120 0.380 0.7
M2 35 2.4 0.706 0.275 0.303 0.741
M3 45 4 0.800 0.458 0.207 0.867
M4 60 6 0.857 0.553 0.148 0.87
M5 100 11 0.917 0.648 0.087 0.89