Skip to main content
. 2023 Apr 18;14:100391. doi: 10.1016/j.resplu.2023.100391

Table 2.

Quality of cardiopulmonary resuscitation (CPR) during assisted training with smart glasses (smart glasses-assisted) and post-test without assistance (N = 12).

M1: while training with smart glasses
M2: Unassisted
post-test
Significance
(Effect size)
Median IQR Median IQR
Mean depth (cm) 4.0 (2.8–5.0) 4.2 (3.2–5.1) p = 0.45*
Mean rate (CC/min) 103 (98–107) 113 (107–122) p = 0.001*
(1.52)
CC with correct release (%) 24 (1–79) 33 (7–92) p = 0.61
CC with correct depth (%) 0 (0–54) 0 (0–45) p = 0.50
CC with correct rate (%) 66 (34–87) 81 (31–97) p = 0.61
CC with correct compression point (%) 100 (1–100) 100 (18–100) p = 0.29
No CC time (in seconds) 0.5 (0.0–1.8) 1.5 (0.0–2.8) p = 0.17

AED: Automated External Defibrillator; CC: Chest compressions. IQR: Interquartile range; Wilcoxon’s signed ranked test (p < 0.05). * Student’s t test (p < 0.05) and Cohen’s d for Effect Size (in brackets).