Skip to main content
. 2023 Apr 17;10:1139398. doi: 10.3389/fvets.2023.1139398

Table 1.

Procedure of lowest impedance for each larynx.

Impedance (kPa * s/L)
Larynx # Surgical procedure CFD EXP
1 LLP 0.177 0.195
2 * LLP 0.026 0.024
2 * LLPCOR 0.026 0.026
3 ** LLPCOR 0.109 0.169
3 ** PA 0.107 0.201
4 LLP 0.030 0.041
5 LLPCOR 0.058 0.084
6 LLP 0.039 0.048
7 LLP 0.055 0.080
8 * LLP 0.067 0.099
8 * LLPCOR 0.065 0.118
9 LLPCOR 0.051 0.093
10 LLP 0.038 0.045

EXP-experimentally measured laryngeal impedance. *For larynges 2 and 8 there were two procedures with lowest impedances that differed by <0.02. **For larynx 3, the CFD and EXP impedance did not agree for the “best” procedure so both are reported for comparison.