Table 6.
EDX | Ultrasound | |||
---|---|---|---|---|
Sensitivity (%) | Specificity (%) | Sensitivity (%) | Specificity (%) | |
Fowler et al 8 | 89 | 80 | 89 | 90 |
Kwon et al 6 | 79 | 83 | 66 | 63 |
Jablecki et al 21 | >85% | >95% | — | — |
Claes et al 7 | 83 | — | 57 | — |
Tai et al 14 | — | — | 87 | 83 |
Azami et al 22 | — | — | 99 | 88 |
Wong et al 23 | — | — | 94 | 65 |
Note. EDX = electrodiagnostic testing; US = ultrasonography.