Table 2.
File name | Variable name | Unit of measure | Description |
---|---|---|---|
Detailed dataset: ds2-detailed-PT1M ds2-detailed-PT5M ds2-detailed-PT30M |
Time | – | The time of the measurement in UTC time |
Tout | C | Outdoor temperature from weather station | |
SolGlob | W/m2 | Horizontal global radiation from weather station | |
SolVerS | W/m2 | Vertical total irradiance on south façade (wall) | |
WindDir | deg | Wind direction from weather station (roof) | |
WindSpd | m/s | Wind speed from weather station (roof) | |
PelInt | W | Electric consumption of manikins and appliances | |
PelPV | W | PV electricity generation | |
CpSp3 | % | Circulation pump set point of radiator circuit | |
EvRad | % | Electronic valve set point of radiator circuit | |
TsRad | C | Supply temperature of radiator circuit | |
TrRad | C | Return temperature of radiator circuit | |
FloRad | l/h | Actual flow of radiator circuit | |
PhRad_actual_power | W | Actual thermal power of radiator circuit | |
PhRad_from_energy | W | Calculated thermal power of radiator circuit | |
EhRad_energy | kWh | Cumulated energy of radiator circuit | |
VolRad | m3 | Cumulated volume of radiator circuit | |
Tv_sup | C | Ventilation air supply temperature | |
Tv_ext_ahu | C | Ventilation extract temperature at AHU | |
Tv_ext_kitchen | C | Ventilation extract temperature at kitchen outlet | |
Ta_technroom | C | Air temperature of technical room | |
RTD29 | C | Temperature of living room south, 0.1 m. a. floor | |
RTD30 | C | Temperature of living room south, 0.8 m.a. floor | |
RTD31 | C | Temperature of living room south, 1.6 m. a. floor | |
RTD32 | C | Temperature of living room south, 2.4 m. a. floor | |
RTD33 | C | Temperature of living room south, 3.2 m. a. floor | |
RTD34 | C | Temperature of kitchen, 1.6 m. a. floor | |
RTD35 | C | Temperature of living room south, 0.1 m. a. floor | |
RTD36 | C | Temperature of living room south, 0.8 m. a. floor | |
RTD37 | C | Temperature of living room south, 1.6 m. a. floor | |
RTD38 | C | Temperature of living room south, 2.4 m. a. floor | |
RTD39 | C | Temperature of living room south, 3.2 m. a. floor | |
RTD40 | C | Temperature of bedroom west, 1.6 m. a. floor | |
RTD41 | C | Temperature of bedroom east, 1.6 m. a. floor | |
RTD42 | C | Temperature of bathroom, 1.6 m. a. floor | |
Minimal dataset: ds2-minimal-PT30M-including-forecasts | Time | – | The time of the measurement in UTC time |
Tout | C | The outdoor temperature from roof mounted the weather station | |
PhRad_actual_power | W | Actual thermal power of radiator circuit | |
QestInt | W | Estimated electric consumption of manikins and appliances | |
Tv_ext_ahu | C | Ventilation extract temperature at the air handling unit | |
Ps | W/m2 | Global horizontal solar irradiance from a satellite irradiance service | |
Ps_for_1 Ps_for_97 | W/m2 | Forecasts of solar irradiance for one step ahead, two steps ahead, etc. Retrieved every 30 min with a forecasting horizon of 48 h | |
Tout_for_1 Tout_for_97 | C | Forecasts of outdoor temperature for one step ahead, two steps ahead, etc. Retrieved every 30 min with a forecasting horizon of 48 h |