Skip to main content
. 2023 Apr 29;8(18):16315–16326. doi: 10.1021/acsomega.3c00979

Table 3. Electrochemical Data Obtained from the Polarization Test for Low-Carbon Steel Immersed in Seawater without and with IBImIL or ImILA for 2 h; the Values are Means of Three Replicates and (±) Corresponds to the Standard Deviations.

inhibitors conc. of inhibitors (mol/L) Ecorr. (V) icorr. (μA/cm2) βa, (mV/dec) –βc, (mV/dec) ηp%
Blank 0.00 0.4174 ± 0.01 835.3 ± 0.2 169.3 ± 0.10 181.2 ± 0.2 0.00
ImILA 1 × 10–4 0.5379 ± 0.02 101.0 ± 0.1 155.8 ± 0.2 169.5 ± 0.4 87.91 ± 0.3
IBImIL 1 × 10–3 0.5674 ± 0.01 49.2 ± 0.02 142.2 ± 0.03 159.4 ± 0.2 94.13 ± 0.2