Skip to main content
. 2023 May 5;13(9):1634. doi: 10.3390/diagnostics13091634

Table 3.

Diagnostic performance of dark-blood late gadolinium enhancement in non-ischemic cardiomyopathy.

Sensitivity Specificity Positive Likelihood Ratio Negative Likelihood Ratio Positive Predictive Value Negative Predictive Value Accuracy
Dark-blood LGE 99 % 99 % 132 0.01 99 % 100 % 99 %
(CI 98–100) (CI 98–100) (CI 55–317) (CI 0.00–0.02) (CI 97–99) (CI 99–100) (CI 99–100)

Table depicts the diagnostic test statistics for the detection of non–ischemic scarring by dark-blood late gadolinium enhancement (LGE). Bright-blood LGE was considered as reference standard. CI = Confidence interval.