Table 4.
Results of the survey
| Median (Q1; Q3) | |
|
How do you evaluate the aerosol release for the different respiratory devices? (No release = 0; Maximum release = 10) | |
| · Laryngeal Mask | 9 (6; 8) * + |
| · Laryngeal Mask + Shower cap | 3 (1; 3) + § |
| · Intubation | 0 (0; 2) * § |
|
How do you evaluate the Rescuers Safety for the different respiratory devices? (1 = Safe; 2 = rather safe; 3 = rather unsafe; 4 = unsafe) | |
| · Laryngeal Mask | 3 (2; 4) * + |
| · Laryngeal Mask + Shower cap | 2 (1; 2) § |
| · Intubation | 1 (1; 2) § |
|
How do you evaluate the Resuscitation Quality for the different algorithms performed? (1 = efficient; 2 = rather efficient; 3 = rather inefficient; 4 = inefficient) | |
| · ERC 2021 | 1 (1; 1) § * + |
| · COVID-19 | |
| · Laryngeal Mask | 2 (1; 2) % $ |
| · Laryngeal Mask + Shower cap | 2 (2; 2) % |
| · Intubation | 2 (2; 3) % § |
|
How do you evaluate the minimization of no-flow-time for the different algorithms performed? (1 = efficient; 2 = rather efficient; 3 = rather inefficient; 4 = inefficient) | |
| · ERC 2021 | 1 (1; 1,25) § * + |
| · COVID-19 | |
| · Laryngeal Mask | 2 (1; 2) % $ |
| · Laryngeal Mask + Shower cap | 2 (1,5; 2) % |
| · Intubation | 2 (2; 3) % ß |
|
How do you evaluate the optimal Rescuers Safety for the different respiratory devices? (1 = Safe; 2 = rather safe; 3 = rather unsafe; 4 = unsafe) | |
| · ERC 2021 | 3 (2; 3)* + |
| · COVID-19 | |
| · Laryngeal Mask | 3 (2; 3) * + |
| · Laryngeal Mask + Shower cap | 2 (1; 2) % § |
| · Intubation | 1 (1; 2) % § |
Legend: *P < 0.001 vs. Laryngeal-Mask + Shower cap
+ p < 0.001 vs. Intubation
§ p < 0.001 vs. Laryngeal-Mask
% p < 0.001 vs. ERC 2021
$ p = 0.01 vs. Intubation
ß = p = 0.01 vs. COVID-19-Laryngeal-Mask
ERC = European Resuscitation Council; COVID-19 = Coronavirus-Disease 2019; Q1 = First Quartile, Q3: Third Quartile