Skip to main content
. 2023 Mar 15;10(5):737–747. doi: 10.1002/mdc3.13710

TABLE 1.

Diagnostic results and methodological aspects for all included studies in the analysis of synucleinopathies versus non‐synucleinopathies

Author TP FN FP TN Sens Spec Assay Cut‐off value
Groveman et al. 2018 27 2 0 31 0.93 1.00 RT‐QuIC Mean of all samples +3SD
Manne et al. 2019 15 0 2 14 1.00 0.88 RT‐QuIC Mean of all samples +10SD
Garrido et al. 2019 18 23 2 8 0.44 0.80 RT‐QuIC Mean of negative controls +2SD
Van Rumund et al. 2019 62 21 5 72 0.75 0.94 RT‐QuIC Mean of negative controls +2SD
Bongianni et al. 2019 43 11 2 57 0.80 0.97 RT‐QuIC Mean of all samples +3SD
Rossi et al. 2020 166 39 10 224 0.81 0.96 RT‐QuIC Mean of neuropathological controls +30SD
Orru et al. 2020 105 3 11 74 0.97 0.87 RT‐QuIC 10% of maximum value
Donadio et al. 2021 6 2 0 26 0.75 1.00 RT‐QuIC Mean of negative controls +3SD
Iranzo et al. 2021 47 5 4 47 0.90 0.92 RT‐QuIC Mean of negative controls +2SD
Bargar et al. 2021 143 3 0 68 0.98 1.00 RT‐QuIC Mean background fluorescence +5SD
Rossi et al. 2021 77 4 20 188 0.95 0.90 RT‐QuIC Mean of negative controls +30SD
Russo et al. 2021 24 4 1 29 0.86 0.97 RT‐QuIC 10% of maximum value
Brockmann et al. 2021 244 54 2 24 0.82 0.92 RT‐QuIC Mean of negative controls +30SD
Poggiolini et al. 2021 113 30 2 53 0.79 0.96 RT‐QuIC Mean of initial fluorescence at 120 h + 5SD
Mammana et al. 2021 22 1 0 57 0.96 1.00 RT‐QuIC 15% of maximum value
Perra et al. 2021 16 0 3 29 1.00 0.91 RT‐QuIC Mean fluorescence during initial 10 h + 10SD
Sokratian et al. 2021 27 4 0 14 0.87 1.00 qRT‐QuIC >200 FFUs/ml
Compta et al. 2022 19 38 4 51 0.33 0.93 RT‐QuIC Mean of negative controls +2SD
Hall et al. 2022 68 13 13 49 0.84 0.79 RT‐QuIC 10% of maximum value
Shahnawaz et al. 2017 85 11 12 85 0.89 0.88 PMCA ≥50 FU
Singer et al. 2020 87 4 0 29 0.96 1.00 PMCA ≥150 AU
Shahnawaz et al. 2020 153 16 0 56 0.91 1.00 PMCA ≥50 FU

Abbreviations: SD, standard deviation; WT, wild type; FFUs, fibril forming units; FU, fluorescence units; AU, arbitrary units.