Table 1. Parameters Used in Base Case Scenarios for Transition between Leaking and Non-leaking States.

component/equipment pLeak MTBF [days] MTTR [days]
valves 0.00191 191,132 366
connectors 0.000665 548,968 365
open ended lines 0.00646 56,536 368
pressure relief valves 0.0272 13,398 375
flanges 0.000665 548,968 365
other 0.000665 548,968 365
tanks 0.046 1515 73
flares 0.1 1435 159