Table 2. Parameters Varied in Sensitivity Analyses and Base Case Simulations.
set of simulations | close-range inspection data sets, which are then combined with the flyover data set | fraction of sites with emissions from close-range inspections when combining close-range and flyover data sets at each Monte Carlo iteration | pLeaka | MTBF [days]a | MTTR [days]a |
---|---|---|---|---|---|
base case | Allen et al.,7 Bell et al.,22 Kuo et al.,23 and Pacsi et al.24b | 0.71 | tanks = 0.046; flares = 0.1 | tanks = 1515; flares = 1435 | tanks = 73; flares = 159 |
sensitivity analysis S0 | Allen et al.,7 Bell et al.,22 Kuo et al.,23 Pacsi et al.,24 ERG,28 and Ravikumar et al.29c | 0.71 | tanks = 0.046; flares = 0.1 | anks = 1515; flares = 1435 | tanks = 73; flares = 159 |
sensitivity analysis S1 | Allen et al.,7 Bell et al.,22 Kuo et al.,23 and Pacsi et al.24b | 0.91 | tanks = 0.046; flares = 0.1 | anks = 1515; flares = 1435 | tanks = 73; flares = 159 |
sensitivity analysis S2 | Allen et al.,7 Bell et al.,22 Kuo et al.,23 and Pacsi et al.24b | 0.51 | tanks = 0.046; flares = 0.1 | anks = 1515; flares = 1435 | tanks = 73; flares = 159 |
sensitivity analysis S3 | Allen et al.,7 Bell et al.,22 Kuo et al.,23 and Pacsi et al.24b | 0.71 | tanks = 0.046; flares = 0.1 | tanks = 103.7; flares = 45 | tanks & flares = 5 |
sensitivity analysis S4 | Allen et al.,7 Bell et al.,22 Kuo et al.,23 and Pacsi et al.24b | 0.71 | tanks = 0.046; flares = 0.1 | tanks = 207.4; flares = 90 | tanks & flares = 10 |
sensitivity analysis S5 | Allen et al.,7 Bell et al.,22 Kuo et al.,23 and Pacsi et al.24b | 0.71 | tanks = 0.046; flares = 0.1 | tanks = 622.2; flares = 270 | tanks & flares = 30 |