Skip to main content
. 2023 May 19;28(2):e2321101. doi: 10.1590/2177-6709.28.2.e2321101.oar

Table 2: Comparison between Multi-strand wire (MS) and Ortho-Flex-Tech™ wire (OFT) retainer groups in terms of the gingival health parameters, IRI, and number of fractured retainers, standard deviation, 95% Confidence Interval, Median and Interquartile.

MS group
Mean (SD)
[95% CI]
OFT group
Mean (SD)
[95% CI]
P-value Median 25 - 75 quartiles 95% CI of
the Difference
PI 0.51 (0.60)
[0.26-0.76]
0.32 (0.51)
[0.10-0.55]
0.157 0.104 0.00 - 0.60 -0.15 - 0.51
GI 0.93 (0.85)
[0.58-1.29]
1.10 (0.63)
[0.82-1.38]
0.459 1.15 0.33 - 1.69 -0.62 - 0.28
CI 0.16 (0.44)
[-0.03-0.34]
0.25 (0.47)
[0.04-0.46]
0.165 0.00 0.00 - 0.00 -0.36 - 0.18
SOHI 0.53 (0.52)
[0.31-0.75]
0.42 (0.40)
[0.24-0.59]
0.759 0.20 0.00 - 1.00 -0.16 - 0.39
IRI (mm) 0.69 (0.71)
[0.51-0.87]
0.00 (0.00)
-
0.048* 0.00 0.00 - 0.00 0.012 - 0.59
FR (n) 2 0 0.384 - - -

Mann-Whitney U test. Chi-square test (only for FR). * Significant (p < 0.05). PI: Plaque index. GI: Gingival index. CI: Calculus index. SOHI: Simplified oral hygiene index. IRI: Irregularity index. FR: Fractured Retainer.