Table 5.
Results of the ablation experiment.
| DCWP module | LR module | Accuracy | Precision | F1-score | Param (M) |
|---|---|---|---|---|---|
| – | – | 0.686 | 0.698 | 0.609 | 0.013 |
| √ | – | 0.790 | 0.793 | 0.753 | 0.780 |
| – | √ | 0.975 | 0.971 | 0.970 | 0.831 |
| √ | √ | 0.993 | 0.988 | 0.987 | 1.577 |
"√ " indicates that there is this module (column name) in this column. For example, the "√" in the second and fourth rows of the "DCWP module" column represents the presence of a DCWP module. The "-" indicates the absence of the module (column name) in this column. For example, the "-" in the first and third rows of the "DCWP module" column represents the absence of a DCWP module.