Design of PV system.
| Number of Photovoltaic (PV) Modules | |||
|---|---|---|---|
| PV Modules in series | 11.0 | No. of strings | 5.0 |
| Total Photovoltaic modules | 55 | Module maximum power | 450 Watt |
| PV array power (STC)) |
24.75 kW |
PV array power (NTC) |
22.84 kW |
| Operating Characteristics of PV Array | |||
| U mpp |
425 V |
I mpp |
54 A |
| Collector Plane Orientation | |||
| Tilt Angle | 15° | Azimuth | 180° |
| Frame size | 8 × 2 Single Axis Tracking | Orientation | Landscape |