Design of PV system.
Number of Photovoltaic (PV) Modules | |||
---|---|---|---|
PV Modules in series | 11.0 | No. of strings | 5.0 |
Total Photovoltaic modules | 55 | Module maximum power | 450 Watt |
PV array power (STC)) |
24.75 kW |
PV array power (NTC) |
22.84 kW |
Operating Characteristics of PV Array | |||
U mpp |
425 V |
I mpp |
54 A |
Collector Plane Orientation | |||
Tilt Angle | 15° | Azimuth | 180° |
Frame size | 8 × 2 Single Axis Tracking | Orientation | Landscape |