Design of PV system.

Number of Photovoltaic (PV) Modules
PV Modules in series 11.0 No. of strings 5.0
Total Photovoltaic modules 55 Module maximum power 450 Watt
PV array power (STC))
24.75 kW
PV array power (NTC)
22.84 kW
Operating Characteristics of PV Array
U mpp
425 V
I mpp
54 A
Collector Plane Orientation
Tilt Angle 15° Azimuth 180°