Skip to main content
. 2023 May 8;9(5):e16105. doi: 10.1016/j.heliyon.2023.e16105

Table 9.

PV module output power variations at different temperature levels.

Temperature (°C) ISC VOC IMP VMP Power dPmp/dT dVmp/dT dVoc/dT
25 11.54 50.0 10.90 41.3 450.1 −0.37% −0.40% −0.33%
30 11.57 49.2 10.92 40.4 441.7 −0.38% −0.41% −0.33%
35 11.61 48.4 10.94 39.6 433.2 −0.39% −0.42% −0.34%
45 11.67 46.7 10.96 37.9 415.9 −0.42% −0.45% −0.36%
55 11.74 45.0 10.99 36.2 398.5 −0.45% −0.47% −0.38%