Table 7. Autoclave Corrosion Inhibition Test Results of the KHCI, Solvent System, and Blank Sample under High TDS and Low Dosage.

samples concentration (ppm) corrosion rate (MPY) inhibition efficiency %
KHCI 20 9.1 43.4
KHCI 100 6.3 60.8
solvent 100 11 29.9
blank   16