Skip to main content
. 2023 May 1;8(20):18047–18057. doi: 10.1021/acsomega.3c01290

Table 8. HPHT Autoclave Corrosion Inhibition Test Results of the KHCI and Blank Under Gas Production Test-2.

samples concentration (dosage %) corrosion rate (MPY) inhibition efficiency %
KHCI 2500 ppm (0.25%) 18 90
MEG 2500 ppm (0.25%) 48 71
blank   167