Table 9. Comparison of Inhibition Efficiencies of the Developed KHCI with Literature Data Relative to Polymeric Inhibitors for Use in CO2-Saturated Brine.
| polymers | metal/alloys | technique used | inhibition efficiency, η (%) |
|---|---|---|---|
| gum arabic42 | C1018 steel | LPR, PDP, and EIS | 83.50 at 5000 ppm |
| dextran derivatives43 | carbon steel | PDP and EIS | 81.10 at 100 ppm |
| modified polyaspartate derivatives44 | C1018 steel | LPR, PDP, and EIS | 53.60–95.0 at 25–100 ppm |
| acrylamide-based terpolymer45 | carbon steel | PDP | 94.6–96.3% at 50–1000 ppm |
| acryloyl-based copolymer (this study) | C1018 steel | LPR and PDP | 84–90 at 100 ppm |