Table 6.
Technique | Sample Requirement | Detection Limit | Principle |
---|---|---|---|
AAS | Metalloenzymes | ppb | Absorption of lights at characteristic wavelengths of the free metal ions |
ICP-OES (ICP-AES) | Metalloenzymes | ppb | Emission of lights at characteristic wavelengths of the excited atoms and ions |
TGA | High enzyme loading and thermal stable support | % | Difference in thermal decomposition temperatures of the enzyme and support |