Table 4.

Precision (P), recall (R), and F1 score (F) for four noisy, contiguous channels. “–” indicate cases in which the precision and F1score are not a number.

SNR
(db)
Interpolation RMS NMI
P R F P R F P R F
−20 100 100 100 100 99.8 99.9 93.0 90.9 92.0
−15 100 100 100 100 99.8 99.9 95.7 100 97.8
−10 100 100 100 100 96.2 98.1 95.7 100 97.8
−5 100 100 100 100 67.6 80.6 95.7 100 97.8
0 100 99.0 99.5 100 15.6 27.0 95.3 93.2 94.3
5 100 13.5 24.0 100 0.30 0.59 88.0 50.0 63.8
10 100 0.52 1.0 0 75.0 27.3 40.0
15 0 0 41.7 11.4 17.9