Table 2.
Number of TPs, FPs, and FNs and time before the device change of the first alarm triggered by the proposed approach for case 1 from customer Cust27.
| Classifier: | Box Plot No Stand. Residuals | Box Plot Stand. Residuals | Mahalanobis Distance | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Time | Feat. | Anticip. | Anticip. | Anticip. | ||||||||||||
| Aggreg. | Subset | TP | FP | FN | FP* | (Days) | TP | FP | FN | FP* | (Days) | TP | FP | FN | FP* | (Days) |
| 3 h | 1 | 0 | 0 | 0 | 65 | 1 | 1 | 0 | 0 | 67 | 1 | 0 | 0 | 0 | 64 | |
| 1 | 0 | 0 | 0 | 65 | 1 | 0 | 0 | 0 | 65 | 1 | 1 | 0 | 0 | 64 | ||
| 1 | 0 | 0 | 0 | 64 | 1 | 0 | 0 | 0 | 99 | 1 | 0 | 0 | 0 | 101 | ||
| 1 | 0 | 0 | 0 | 63 | 1 | 0 | 0 | 0 | 101 | 1 | 0 | 0 | 0 | 100 | ||
| 1 | 0 | 0 | 0 | 98 | 1 | 0 | 0 | 0 | 101 | 1 | 0 | 0 | 0 | 97 | ||
| 1 | 0 | 0 | 0 | 63 | 1 | 0 | 0 | 0 | 101 | 1 | 0 | 0 | 0 | 98 | ||
| 1 | 0 | 0 | 0 | 88 | 1 | 0 | 0 | 0 | 101 | 1 | 0 | 0 | 0 | 64 | ||
| 1 | 1 | 0 | 0 | 88 | 1 | 0 | 0 | 0 | 100 | 1 | 0 | 0 | 0 | 100 | ||
| 0 | 0 | 1 | 0 | - | 1 | 0 | 0 | 0 | 101 | 1 | 0 | 0 | 0 | 100 | ||
| 1 | 0 | 0 | 0 | 88 | 1 | 0 | 0 | 0 | 100 | 1 | 0 | 0 | 0 | 101 | ||
| 1 | 0 | 0 | 0 | 96 | 1 | 0 | 0 | 0 | 101 | 1 | 0 | 0 | 0 | 98 | ||
| 4 h | 1 | 0 | 0 | 0 | 64 | 1 | 0 | 0 | 0 | 66 | 1 | 0 | 0 | 0 | 64 | |
| 1 | 0 | 0 | 0 | 64 | 1 | 0 | 0 | 0 | 63 | 1 | 0 | 0 | 0 | 64 | ||
| 1 | 0 | 0 | 0 | 63 | 1 | 0 | 0 | 0 | 100 | 1 | 0 | 0 | 0 | 99 | ||
| 0 | 0 | 1 | 0 | - | 1 | 0 | 0 | 0 | 100 | 1 | 0 | 0 | 0 | 99 | ||
| 1 | 0 | 0 | 0 | 100 | 1 | 0 | 0 | 0 | 100 | 1 | 0 | 0 | 0 | 99 | ||
| 1 | 0 | 0 | 0 | 63 | 1 | 0 | 0 | 0 | 100 | 1 | 0 | 0 | 0 | 100 | ||
| 1 | 1 | 0 | 0 | 64 | 1 | 0 | 0 | 0 | 100 | 1 | 0 | 0 | 0 | 99 | ||
| 0 | 0 | 1 | 0 | - | 1 | 0 | 0 | 0 | 98 | 1 | 0 | 0 | 0 | 99 | ||
| 1 | 0 | 0 | 0 | 88 | 1 | 0 | 0 | 0 | 100 | 1 | 0 | 0 | 0 | 99 | ||
| 1 | 0 | 0 | 0 | 88 | 1 | 0 | 0 | 0 | 100 | 1 | 0 | 0 | 0 | 99 | ||
| 1 | 0 | 0 | 0 | 88 | 1 | 0 | 0 | 0 | 100 | 1 | 0 | 0 | 0 | 99 | ||