Skip to main content
. 2023 May 29;13:8712. doi: 10.1038/s41598-023-35498-6

Table 2.

Corrosion criterions from WL for C-steel dissolution in 1.0 M HCl in the presence and absence of inhibitors at the studied temperatures.

Inhibitor Conc., M 298 K 308 K 318 K 328 K
CR × 10−3 mg cm−2 min−1 ɳ% CR × 10−3 mg cm−2 min−1 ɳ% CR × 10−3 mg cm−2 min−1 ɳ% CR × 10−3 mg cm−2 min−1 ɳ%
MA-1440 1.0 M HCl 10.1 17.7 40 80.4
5 × 10−6 2.64 73.91 4.00 77.37 7.47 81.33 13.87 82.74
10 × 10−6 2.37 77.00 3.54 80.39 6.45 84.31 11.72 85.83
15 × 10−6 2.13 80.04 3.11 83.50 5.48 87.38 9.62 89.11
20 × 10−6 1.90 82.71 2.69 86.22 4.56 90.05 7.630 91.96
25 × 10−6 1.70 84.21 2.30 88.04 3.78 91.59 5.83 93.78
30 × 10−6 1.55 84.71 2.00 88.74 3.12 92.25 4.31 94.69
MA-1456 5 × 10−6 3.28 67.64 4.75 73.18 9.07 77.33 15.86 80.27
10 × 10−6 3.01 70.73 4.29 76.17 7.99 80.45 13.80 83.25
15 × 10−6 2.74 74.01 3.86 79.29 7.04 83.50 11.94 86.23
20 × 10−6 2.49 76.86 3.45 81.95 6.13 86.12 10.27 88.68
25 × 10−6 2.26 78.71 3.10 83.52 5.37 87.62 8.73 90.17
30 × 10−6 2.07 79.62 2.81 84.19 4.75 88.19 7.40 90.85