Figure 4.
Examples of pathologic conduction patterns within the AcQMap system. (A) Focal firing is defined as electrical activity that radially propagates outward from a given position. (B) Localized partial rotational activity is propagation that rotates greater than 270 degrees around a given position. (C) Localized irregular activity propagation that pivots and refracts (changes direction) greater than 90 degrees as it moves through a given position.