Skip to main content
. 2023 May 31;13:8797. doi: 10.1038/s41598-023-34537-6

Table 2.

Statistical comparison between the results obtained using the proposed spectrophotometric method and the reported HPLC method for Molnupiravir assay8.

Parameter D0 method Reported methoda
Mean 100.32 99.62
SD 1.624 0.795
n 6 6
Variance 2.637 0.632
Student's t-testb 0.972 (2.228)
F-testb 4.173 (5.05)

aHPLC method using a C18 column, water: acetonitrile (80:20) as mobile phase, and UV-detection at 240 nm.

bThe values in parentheses are the corresponding theoretical values for t and F at P = 0.05.