Skip to main content
. 2022 Dec 7;15(3):454–462. doi: 10.4055/cios22128

Table 4. Comparison of PRTEE Scores between US-Guided PRP Group and US-Guided Steroid Group at Timely Intervals (n = 64).

PRTEE Group p-value
PRP (n = 32) Steroid (n = 32)
Presentation 43.40 ± 9.53 45.34 ± 10.09 0.433
2 wk 39.50 ± 9.15 30.68 ± 10.18 0.001*
p-value 0.768 0.310
1 mo 23.53 ± 7.19 19.5 ± 3.76 0.007*
p-value 0.100 0.019
3 mo 10.81 ± 5.36 8.71 ± 2.41 0.048*
p-value 0.005 < 0.001
6 mo 6.87 ± 2.75 6.06 ± 2.07 0.188
p-value < 0.001 < 0.001
1 yr 5.18 ± 1.71 7.25 ± 1.58 < 0.001*
p-value < 0.001 < 0.001
2 yr 3.96 ± 1.51 7.53 ± 1.19 < 0.001*
p-value < 0.001 < 0.001

Values are presented as mean ± standard deviation.

PRTEE: Patient-Rated Tennis Elbow Evaluation, US: ultrasound, PRP: platelet-rich plasma.

Statistically significant: *Unpaired t-test. Paired t-test.