Skip to main content
. 2023 May 18;10:1162124. doi: 10.3389/fmed.2023.1162124

TABLE 4.

Localization performance with IOU metric on the SMC dataset.

Networks Localization method Mean IOU
(Threshold = 0.45)
Baseline (ResNet-50) Grad-CAM 0.175
Proposed method LGM
(between ResNet layer 3 and 4)
0.489

IOU, intersection over union; SMC, Samsung Medical Center; Grad-CAM, gradient-weighted class activation mapping; LGM, lesion guiding module.