| Predicted proportion of patients screened given different baseline control proportions | |||
| Combinations of QI strategies (no. of arms) |
30% baseline screening (95% CrI) |
50% baseline screening (95% CrI) |
70% baseline screening (95% CrI) |
| Most common combinations of QI strategies observed 3 or more times in included studies reporting foot screening | |||
| CM + TC + PE + PSM (n = 6) | 0.73 (0.51 to 0.88) | 0.87 (0.70 to 0.95) | 0.94 (0.85 to 0.98) |
| CM + PE + PSM (n = 3) | 0.58 (0.35 to 0.79) | 0.76 (0.56 to 0.90) | 0.88 (0.75 to 0.95) |
| CE + CR + AF (n = 3)a | 0.47 (0.30 to 0.65) | 0.67 (0.50 to 0.81) | 0.83 (0.70 to 0.91) |
| Sequential combinations of the most effective 5 QI strategies as estimated from the model for foot screening | |||
| PE + TC | 0.66 (0.41 to 0.84) | 0.82 (0.61 to 0.93) | 0.91 (0.79 to 0.97) |
| PE + TC + Other | 0.75 (0.50 to 0.90) | 0.88 (0.70 to 0.95) | 0.94 (0.84 to 0.98) |
| PE + TC + Other + PR | 0.81 (0.48 to 0.95) | 0.91 (0.68 to 0.98) | 0.96 (0.83 to 0.99) |
| PE + TC + Other + PR + CR | 0.84 (0.54 to 0.96) | 0.93 (0.73 to 0.98) | 0.97 (0.87 to 0.99) |