Skip to main content
. 2023 May 15;8(21):18509–18515. doi: 10.1021/acsomega.3c00171

Table 1. Comparison of Kinetic Model Values for FY AB and RBV-5R Dyes.

pseudo-first-order
pseudo-second-order
FY-AB RBV-5R FY-AB RBV-5R
qe = 4.478 mg g–1 (experimental) qe = 5.1047 mg g–1 (experimental) qe = 4.694 mg g–1 qe = 5.260 mg g–1
qe = 0.001435 mg g–1 (calculated) qe = −0.059 mg g–1 (calculated) K2 = 25.206 min–1 K2 = 71.253 min–1
K1 = 0.0428 min–1 K1 = 0.001169 min–1 R2 = 0.9973 R2 = 0.9997
R2 = 0.9465 R2 = 0.9853