Skip to main content
. 2023 May 18;8(21):18530–18542. doi: 10.1021/acsomega.3c00264

Table 2. Comparison between the Measured and CFD Results at the Boiler Exit for the SY Sample for the Reference Case.

parameters measured data simulation data error, %
O2 (% dry) 2.60 2.62 0.02%
flue gas temperature (K) 628 623 5 K
NOx emission (ppm, 6% O2) 118 116 2 ppm
UBC (wt %) fly ash 1.58 1.54 0.04%
bottom ash 41.50 40.71 0.79%