Table 3. Comparison between the Heat Absorption of the Measured and CFD Results in Relation to the Heat Exchangers for the Reference Case.
parameters | measured data | CFD | errora | |
---|---|---|---|---|
heat absorption (MW) | evaporator and boiler bank | 158.1 | 158.6 | 0.31% |
platen | 21.4 | 20.6 | 3.73% |
Error = abs (CFD - measured) × 100/measured.