Table 3.
Category | Parameter | Performance |
---|---|---|
Application | Channel types | 2 (flow)+1 (vacuum) |
Fluid type | Liquid, Gas and Vacuum | |
Liquid flow range | 1.5 - 68 Lmin | |
Gas flow range | 1.3 - 20.7 mL min-1 | |
Vacuum range | 157 - 556 mbar | |
Flow profile | Fluctuation-free | |
Architecture | Platform size (L W H) | 29 cm 24 cm 22 cm |
Weight | 4.8 kg | |
Cost | € 5600 | |
Control | Function | Process control |
Controllability | Linear | |
Liquid: 0.8 Lmin | ||
Resolution | Gas: 0.2 mL min-1 | |
Vacuum: 3 mbar | ||
Liquid: 0.58 % RSD* | ||
Flow stability | Gas: 0.56 % RSD* | |
Vacuum: 0.16 % RSD* | ||
Liquid: 4.5 s | ||
Settling time | Gas: 14 s | |
Vacuum: 2 s | ||
Battery | Power consumption | Minimum: 0.5 W |
Maximum: 18.5 W | ||
Battery worktime | Minimum: 3 h | |
Maximum: 96 h |
aDI water is the tested liquid. The value may change if the liquid changes
bThe fluid is the air at a temperature of 20C