Table 1.
Mean diameter of ION@Dex, ION@PVA, and ION@PLGA determined via TEM and of XRD data with the Scherrer equation. For ION@PLGA the Scherrer diameter could not be calculated because the thick coating leads to small reflexes even with intense measurement time. IEPs of ION@Dex, ION@PVA, and ION@PLGA. Hydrodynamic diameters of BIONs, ION@Dex, ION@PVA, and ION@PLGA in SBF and human blood plasma at 37 °C.
Particles | TEM diameter dTEM [nm] | Scherrer diameter dScherrer [nm] | Isoelectric point (IEP) | Hydrodynamic diameters in SBF [nm] | Hydrodynamic diameters in human blood plasma [nm] |
---|---|---|---|---|---|
BIONs | 1905 ± 345 | 326 ± 17 | |||
ION@Dex | 10.5 ± 2.1 | 8.6 ± 0.5 | 6.9 | 1416 ± 684 | 238 ± 18 |
ION@PVA | 10.6 ± 2.1 | 8.8 ± 1.6 | 7.4 | 211 ± 7 | 238 ± 15 |
ION@PLGA | 9.5 ± 2.1 | – | 2.9 | 841 ± 81 | 133 ± 1 |