1 |
Waters QuanRecovery 700 μL
Plates (Waters, Milford, USA) |
Incubator Hood TH 30 (Edmund
Buhler GmBH, Bodelshausen, Germany) |
Corning clear polystyrene 96-well microplate lids
(Thermo Fisher
Scientific, Loughborough, UK) secured with SLS heat resistant laboratory
tape (Scientific Laboratory Supplies, Nottingham, UK) |
|
2 |
Waters QuanRecovery
700 μL Plates |
Incubator Hood TH 30 |
Waters 96-well 7 mm round plug silicone/PTFE cap mat (Waters,
Milford, USA) topped with the Corning lid sealed with tape |
|
3 |
Waters
QuanRecovery 700 μL Plates |
Grant SUB6 Universal
Water Bath (Grant Instruments, Cambridge,
UK) |
Waters silicone/PTFE cap mat topped with the Corning
lid and
sealed with tape |
|
4 |
Waters QuanRecovery 700 μL Plates |
Dry bath heater (Star Lab, Milton Keynes, UK) filled with Bath
Armor heating beads (Appleton Woods Ltd., Birmingham, UK) |
Waters silicone/PTFE cap mat topped with the Corning lid and
sealed with tape |
|
5 |
Eppendorf twin.tec semiskirted 250 μL 96-well
plates
(Eppendorf, Hamburg, Germany) |
Thermo Scientific Hybaid
PX2 thermal cycler (Thermo Fisher Scientific, Loughborough,
UK) |
Eppendorf Flat Microcap 8-Strips (Eppendorf, Hamburg,
Germany) |
|
6 |
Eppendorf twin.tec semiskirted 250 μL 96-well plates |
Thermo Scientific Hybaid PX2 thermal cycler |
Eppendorf Flat Microcap 8-Strips |
Starting
reagents adjusted to 70 μL AmBic and 5 μL
bovine serum albumin (BSA, 0.1 mg/mL) |