Skip to main content
. 2023 Jun 2;13(11):1947. doi: 10.3390/diagnostics13111947

Table 10.

Quantitative Results of Fine-tuned SAM on Retinal Vessel Segmentation Datasets.

Dataset Dice (Manual) Dice (Fine-Tuned) Dice Relative Increase IoU (Manual) IoU (Fine-Tuned) IoU Relative Increase
DRIVE [38] 0.2267 0.7733 241% 0.1281 0.6304 392%
CHASEDB1 [41] 0.1685 0.7118 322% 0.0921 0.5526 500%
HRF [42] 0.1701 0.6776 298% 0.0931 0.5124 450%
STARE [40] 0.1902 0.7694 304% 0.1057 0.6252 491%