Skip to main content
. 2023 May 25;15(11):2454. doi: 10.3390/polym15112454

Table 9.

Comparison of the NENSIF values obtained from the fracture tests on notched polymeric samples with those predicted by the VO-MS criterion.

ρ (mm) Loading Angle,
β (°)
Mean Experimental NENSIF Predicted NENSIF Discrepancy (%)
1 0 (mode I) 1 1 0
40 1.04 1.0 4.2
65 1.1 1.0 9.5
72 1.16 1.0 13.2
90 (mode III) 1.47 1.35 8.4
Avg.: 8.8
2 0 (mode I) 1 1 0
40 1.09 1.0 8.3
65 1.19 1.01 14.8
72 1.10 1.02 6.5
90 (mode III) 1.56 1.41 9.6
Avg.: 9.8
4 0 (mode I) 1 1 0
40 1.04 1.0 4.0
65 1.20 1.02 14.9
72 1.25 1.04 16.8
90 (mode III) 1.57 1.46 6.4
Avg.: 10.5
Avg.: 9.7