Ambient temperature |
25 |
|
Ambient pressure |
101.3 |
|
,
|
Compressor and pump pressure ratio |
1.19 |
|
Isentropic efficiency of air and fuel compressors |
0.85 |
|
Isentropic efficiency of water pump |
0.85 |
|
After burner chamber efficiency |
0.99 |
|
Inlet water temperature of hot water HX |
25 |
|
Inlet water pressure of hot water HX |
101.3 |
|
Outlet water temperature of hot water HX |
25 |
|
Absorption chiller generator temperature |
80 |
|
Absorption temperature |
30 |
|
Condenser temperature |
30 |
|
Evaporator temperature |
2 |
|
Inlet and outlet exhaust gas temperature difference of the generator |
8 |
|
The temperature of the inlet cold water of condenser and absorber |
25 |
|
The inlet pressure of the cool water of condenser and absorber |
101.3 |
|
The temperature of the outlet cold water of condenser and absorber |
35 |
|
Inlet cold water temperature of the evaporator |
12 |
|
Inlet cold water pressure of the evaporator |
101.3 |
|
Outlet cold water temperature of the evaporator |
7 |
|
Efficiency of solution HX |
0.8 |
|
Efficiency of solution pump |
0.8 |
|
Faraday constant |
96485 |
|
Fuel cell inlet temperature |
726.85 |
|
Fuel cell outlet temperature |
826.85 |
|
Fuel utilization factor of fuel cell |
0.85 |
|
Area of single fuel cell |
0.01 |
|
Current density |
8000 |
|
Inverter efficiency |
0.97 |
|
Anode current density |
6500 |
|
Current density of cathode |
2450 |
|
Cathode effective diffusion coefficient |
2E-5 |
|
Anode effective diffusion coefficient |
5E-6 |
|
Number of fuel cells |
11000 |
|
Vapor to carbon ratio |
2.5 |
|
Anode thickness |
5E-4 |
|
Cathode thickness |
2E-5 |
|
Electrolyte thickness |
1E-5 |
|
Connection thickness |
0.003 |