TABLE III.
Individual and average time constants and corresponding variance accounted for (R2) when fitting the exponential function for each listening condition. τ units are in ms, and the ± error of the average time constants is the SEM of the individual time constants.
| 4 kHz off-frequency | 4 kHz masker absent | ||||
|---|---|---|---|---|---|
| Subjects | τ | R2 | τ | R2 | |
| S1 | 73.40 | 0.96 | 78.80 | 0.98 | |
| S2 | 61.45 | 0.87 | 53.59 | 0.99 | |
| S3 | 33.75 | 0.97 | 56.77 | 0.87 | |
| S4 | 48.68 | 0.79 | 171.90 | 0.98 | |
| S5 | 33.60 | 0.86 | 67.56 | 0.96 | |
| S6 | 29.20 | 0.88 | 60.42 | 0.98 | |
| S7 | 43.17 | 0.96 | 56.73 | 0.96 | |
| S8 | 49.45 | 0.93 | 96.40 | 0.98 | |
| S9 | 43.93 | 0.96 | 61.54 | 0.97 | |
| Average | 46.29 ± 4.72 | 0.91 | 78.19 ± 12.55 | 0.96 | |