Table 2.
Postprocess | Purpose |
---|---|
Wake vs. Sleep | Increase sensitivity to wake states by combining the probability of Active and Quiet Wake to determine wake vs. sleep, then determining most probable wake state. |
Wake to REM | Ablate REM episode when an invalid Wake to REM transition occurs. |
End of REM | End a REM episode if the probability of REM declines past a moving average. |
Minimum REM Duration | Force REM episodes to be a minimum duration via a backwards pass. |
Valid Transitions | Repair a sequence of states to the most probable physiologically possible sequence of states (Fig. 6). |