Detection of total arrhythmia events with a 24‐h Holter monitor versus a 7‐day MEMO patch monitor.

MEMO patch monitor 24‐h Holter monitor p‐value
Number of participants diagnosed with arrhythmias 29/58 (50.0%) 17/58 (29.3%) .001
Number of detected arrhythmias 51 22 <.001
Supraventricular tachycardia 17 8 .042
Atrial fibrillation/atrial flutter 6 2 .143
Atrial premature beats 4 4 1.000
Ventricular premature beats 5 5 1.000
Tachycardia‐bradycardia syndrome 1 0 .315
Sinus pause (≥3 s) 1 1 1.000
Second‐degree (Mobitz type I) AVB 4 2 .402
Second‐degree (Mobitz type II) AVB 0 0
Intermittent 2:1 AVB 1 0 .315
Third‐degree AVB 0 0
Wolff–Parkinson–White syndrome 1 0 .315
Sick sinus syndrome 1 0 .315
Short run of accelerated idioventricular rhythm 1 0 .315
Ventricular tachycardia (≥3 events) 1 0 .315
Polymorphic ventricular tachycardia/ventricular fibrillation 0 0

Abbreviation: AVB, atrioventricular block.