Skip to main content
. 2023 May 31;14:1164444. doi: 10.3389/fendo.2023.1164444

Table 3.

Area under the receiver operating characteristic curve of the value of FT3 for predicting 30-day mortality.

Total (N=96) AUC (95%CI) Cut-off value Sensitivity (%) Specificity (%)
Overall patients 96 0.774(0.678, 0.854) 3.58 88.46 62.86
Gender
 Male 41 0.767(0.609, 0.884) 3.58 86.67 65.38
 Female 55 0.809(0.680, 0.902) 3.43 90.91 68.18
Age
 ≥50 years 31 0.724(0.535, 0.868) 3.52 90.00 52.38
 <50 years 65 0.786(0.666, 0.878) 3.12 81.25 77.55
LVEF at admission
 ≥40% 54 0.765(0.630, 0.870) 3.01 77.78 80.00
 <40% 42 0.778(0.623, 0.891) 3.58 88.24 64.00
MCS
 Yes 46 0.756(0.607, 0.870) 2.72 53.33 87.10
 No 50 0.779(0.639, 0.884) 3.58 81.82 82.05

LVEF, left ventricular ejection fraction; MCS, mechanic circulatory support.