Accuracy of initial telestroke diagnosis.

Final diagnosis
Stroke/TIA Stroke mimic
Initial diagnosis Stroke/TIA True positive 532 False positive 36 PPV = 93.7%
Stroke mimic False negative 12 True negative 170 NPV = 93.4%
Sensitivity = 97.8% Specificity = 82.5%

Accuracy of telestroke diagnosis. Patients with uncertain diagnosis during initial consultation or after final evaluation were not included in the analysis.