Table 2. Parameters of laser pulse trains employed for psychophysical tests. Definitions: GBS – grating-based pulse stretcher; FBS – fiber-based pulse stretcher; τ – pulse duration at full width at half maximum; PRF – pulse repetition frequency; δ – duty cycle; λc – central wavelength, the fiber length is indicated; Δλ – spectral full width at half maximum; D – beam diameter (1/e2) at the pupil plane (for elliptical beams, both axis sizes are provided); N – number of tested subjects.

Laser source Modification τ [ps] PRF [MHz] δ λc [nm] Δλ [nm] D [mm] N
tunable fs laser –––– 0.197 51.5 1.01 × 10–5 1042.1 9.9 2.1 × 1.4 4
fs laser –––– 0.253 62.65 1.58 × 10–5 1043.3 4.8 1.5 15
fs laser GBS 2 62.65 1.25 × 10–4 1043.3 5.3 1.2 × 1.6 8
ps laser –––– 12.2 19.17 2.34 × 10–4 1028.4 12.5 2.1 15
fs laser FBS (100 m) 44.9 62.65 2.81 × 10–3 1043.3 10.3 1.85 4
ps laser FBS (1 km) 92.4 19.17 1.77 × 10–3 1029.3 7.5 2.0 4
fs laser FBS (100 m) 269 62.65 1.69 × 10–2 1043.3 18.4 1.6 4
fs laser FBS (1 km) 759 62.65 4.70 × 10–2 1043.3 6.8 1.6 3