Skip to main content
. 2023 Jun 21;13:10102. doi: 10.1038/s41598-023-37167-0

Table 6.

The optimum conditions for chlorophyll a and TOC removal.

Parameters pH Time Pressure Flow Distance O3 H2O2 EF1 EF2 S/N
Test 5 for chlorophyll a removal 7 60 5 1 25 2 2 98 98.61 39.85
Optimization condition for chlorophyll a removal 5 90 5 1 25 3 2 100 100 40
Test 5 for TOC removal 7 60 5 1 25 2 2 79.5 81 38.08
Optimization condition for TOC removal 5 90 5 1 25 3 2 100 100 40

Significant values are in bold.