Table 5. Power Law and Cross Model Fitted Data.

  power law
cross model
CMC wt % τ0 (mPa) k (mPa·s) R2 η0 (mPa·s) η (mPa·s) n k (mPa·s)
0.5 5.0 88.5 0.99 94.6 1.1 × 10–5 1.1 0.03
0.75 37.8 273.1 0.99 346.9 3.2 × 10–5 0.6 0.03
1 217.6 741.2 0.99 1180.9 3.1 × 102 0.7 0.2