Skip to main content
. 2023 Jun 22;39:15. doi: 10.5758/vsi.230019

Table 2.

Aneurysm characteristics, operative and dosimetric data of five male who underwent EVAR with the CEXC

Patient 1 Patient 2 Patient 3 Patient 4 Patient 5
Disease status Asymptomatic Asymptomatic Asymptomatic Ruptured Symptomatic
Classification Infrarenal Infrarenal Infrarenal Infrarenal Infrarenal
Aneurysmal sac diametera (mm) 52.0 54.0 50.2 131.0 58.5
Proximal aortic neck length (mm) 13.0 18.0 20.0 25.0 13.2
Proximal aortic neck diameter (mm) 22.0 27.0 22.5 21.0 25.0
Proximal aortic neck angulation (°) 40.0 12.0 63.0 90.0 33.7
Conical neck No No No No No
Neck thrombus or calcification <2 mm/<25% of circumference <2 mm/<25% of circumference <2 mm/<25% of circumference <2 mm/<25% of circumference <2 mm/<25% of circumference
Anesthesia type General General General General General
Contrast agent volume (mL) 125 150 150 180 200
Procedure duration (min) 115 120 125 180 105
Blood transfusion (unit) - - - 4 -
Postoperative hospitalization (d) 1 1 2 11 1
Kerma-area productb (mGym2) LDF 2.40 0.98 3.33 NA 3.72
HDF 0.30 0.38 0.46 NA 0.78
Total 2.70 1.36 3.79 20.10 4.50
Fluoroscopy time (sec) LDF 786 547 1,253 NA 1,090
HDF 38 80 66 NA 84
Total 824 627 1,319 3,540 1,174

EVAR, endovascular aneurysm repair; CEXC, GORE EXCLUDER Conformable abdominal aortic aneurysm Endoprosthesis (W. L. Gore and Associates); LDF, low-dose fluoroscopy; HDF, high-dose fluoroscopy; NA, not available.

aInner wall-to-inner wall. bMobile C-arm fluoroscopy equipment with a maximum field-of-view of 31 cm at the plane of the image intensifier (Philips BV Pulsera; Philips Medical Systems).