Skip to main content
. 2023 Jun 21;17:1691–1699. doi: 10.2147/OPTH.S405924

Table 2.

Occurrence of Complications in Long Needle Track and Short Needle Track Ahmed Glaucoma Valve Implantation

Group Total N = 41 P-value
Long N = 20 Short N = 21
Complications
Corneal Bullae 1 (5%) 0 (0%) 1 (2.4%) 0.149
Filamentary Keratitis 0 (0%) 1 (4.8%) 1 (2.4%) 0.161
Early flat chamber / Shallow AC 0 (0%) 3 (14.3%) 3 (7.3%) 0.039*
Iris plug 0 (0%) 1 (4.8%) 1 (2.4%) 0.161
Malignant Glaucoma 1 (5%) 0 (0%) 1 (2.4%) 0.149
Plate exposure 1 (5%) 0 (0%) 1 (2.4%) 0.149
Post operative hyphema 1 (5%) 1 (4.8%) 2 (4.9%) 0.484
Post-operative hypotony 1 (5%) 2 (9.5%) 3 (7.3%) 0.287
Decompression retinopathy 0 (0%) 1 (4.8%) 1 (2.4%) 0.161
Vitreous hemorrhage 1 (5%) 0 (0%) 1 (2.4%) 0.149

Note: *Statistically significant.