Skip to main content
. 2023 Jun 23;45(1):2224888. doi: 10.1080/0886022X.2023.2224888

Table 3.

Procedure characteristics.

  Patient #1 Patient #2 Patient #3 Patient #4 Patient #5 Patient #6 Patient #7 Patient #8 Patient #9 Patient #10
Procedural characteristics                    
 Transfemoral access Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
 Prosthesis type Sapien 3 Sapien 3 Evolut R Corevalve Evolut R Sapien 3 Sapien 3 Sapien 3 Sapien 3 Sapien 3
 Prosthesis size, mm 29 29 26 31 29 26 29 26 26 26
 Valve embolization No No No No No No No No No No
 Residual mean aortic gradient, mmHg 6 5 8 15 9 4 7 9 5 4
 Residual aortic regurgitation Trivial Trivial Mild Mild-to moderate Mild Mild None None Trivial None
 Volume of contrast, mL 40 160 77 60 40 45 35 35 33 45
 Need for percutaneous coronary intervention ‘ No No No No Yes Yes No No No No